Style VFL

Overview

Our steam service ratings are very low in the interest of safety although our 70°F (21°C) pressure ratings are as high or higher then our competitors. All locations where failure could lead to personal injury or suffocation must be avoided. In dangerous locations we suggest housed expansion joints, solid loops, ball joints, packed devices etc. rather than thin walled flexible products regardless of manufacturer.

Consult factory with full location description as well as service conditions for higher pressure or temperature applications.

304 SS can be used up to 850°F (454°C) in applications such as engine exhaust.

When using VFL products in copper or brass water or steam systems, dielectric flanges must be used on each end to prevent leakage from galvanic action.

Series VFL – 4 x 49

Style VFL

Rated Pressures at Elevated Temperatures

(psi) (kg/cm2)

Hose Size Factor 0.92 Factor 0.86 Factor 0.81
in - mm 250°F - 121° C 350°F - 176° C 450°F - 232° C
2 - 50 330 - 23 310 - 21 290 - 20
2-1/2 - 65 270 - 19 250 - 17 235 - 16
3 - 80 260 - 18 240 - 16 230 - 16
4 - 100 210 - 15 200 - 14 190 - 13
5 - 125 190 - 13 180 - 12 170 - 11
6 - 150 190 - 13 180- 12 170 - 11
8 - 200 170 - 11 160 - 11 150 - 10
10 - 250 160 - 11 150 - 10 140 - 9
12 - 300 160 - 11 150 - 10 140 - 9

Style VFL

Product File Downloads

Our expert team at Mercer Rubber is eager to collaborate and engineer custom solutions that meet your specific needs. Let’s turn your vision into reality – Contact us now!